Starting guide Atom R8

Atom 4R6AD

Atom 8R - The extension module is designed to control powerful loads using 6 relays with a switching current of 16A. Great for automating electric heating.

Functional elements

Atom R8
1. 9-48V DCPower supply
2. CAN bus ensures synchronized operationof all Atom series devices
3. 5V and 3.3V connectorsfor sensors power supply
4. 2 х 5A relaysfor connecting electrical appliances
5. 6 х 16A relays for connecting electrical devices


Technical specifications

Note : Technical specifications, connection diagrams, output specifications and other technical information can be viewed on our websiteAtom R8

Installation guide

Important! During installation and operation, observe the general rules of electrical safety regarding the use of electrical appliances, as well as the requirements of regulations on electrical safety. It is strictly forbidden to disassemble a device to which any conductors are connected!

Atom series extension controllers require pre-configuration:


1. Installation

Install the controller and power supply to the DIN rail. Make sure there are no signs of mechanical damage or condensation. If necessary, install additional switchboard equipment - contactors, circuit breakers, power supplies and other automation devices.


2. Power supply

Connect the power supply to the mains via the circuit breaker. Connect the power supply output to the controller's power connector.
Controller power connectors, sensor power outputs and load control outputs for easy installation are made in the form of removable connectors with screw terminals.

Important! Although the controller has built-in protection against incorrect power connection, and in this situation will not fail, we recommend that you pay attention to the correct polarity when connecting.

Power supply Atom R8


3. i3-NET

Connect the extension controller to an i3-NET network. Install the end terminators included in the equipment kit at the ends of the bus.

i3 Net Atom R8

4. Sensors power supply

A 5V and 3.3V controller outputs are provided to power the sensors.

Important! If the system uses sensors or actuators with other operating voltages, use additional power supplies or the power supply that powers the controller. If the system uses several power supplies - connect their "negative" terminals to each other.

5.Output connections

Connect the controlled devices to the outputs. Each output is implemented in the form of a 2-pin connector and is designed to connect conductors with a cross-section up to 2.5 mm2. One of the contacts is marked "OUT". The load is connected according to the type of output.
Examples of connecting loads to Extension 8R are given below

OUT1-OUT6 - relay outputs with switching current up to 16A (active load), designed for switching direct and alternating current loads with a voltage of up to 250V.
Outputs are intended for connecting powerful loads: lighting groups, pumps, fans, electric motors, boilers, electric heating devices.

OUT Atom R8

OUT7-OUT8 - relay outputs with switching current up to 5A (active load), designed for switching direct and alternating current loads with a voltage of up to 250V.
Best suited for controlling low-power loads: thermal heads, low-power LED lamps and lights, devices with dry contact type inputs (garage gates, impulse blinds), intermediate relays, emergency lighting, electric locks.

OUT Atom R8

6. Done. Turn on the power

Important! Check all connections. Make sure that the power supply, inputs and outputs are connected correctly.

List of typical problems and their solutions

  • The device is turned on, but is not visible in the application settings

    1. Check the presence of supply voltage on the module2. Check the polarity of the power supply

  • The load does not turn on or reacts incorrectly

    1. Check the correctness and reliability of the connection2. Check if the connected load operates properly