Thank you!
We will contact you shortly.
Starting Guide Atom Carbon +R3
Atom Carbon +R3
He is a "heavyweight" in the Atom team. Designed to control powerful loads, as it is equipped with relay outputs with switching currents of 16 A and 26 A. You will not only be able to turn on powerful devices, but also conveniently organize controlled sockets for equipment with high starting currents.
Modifications
Functional elements
Outputs
LED Indication
1. Device status indication
2. LAN connection indication
4. Output ports type and status indication
Technical specifications
Note : Technical specifications, wiring diagrams, input and output specifications and other technical information can be viewed on page Atom Carbon +R3
Important! During installation and operation, observe the general rules of electrical safety regarding the use of electrical appliances, as well as the requirements of regulations on electrical safety. It is strictly forbidden to disassemble a device to which any conductors are connected!
Important! Although the controller has built-in protection against incorrect power connection, and in this situation will not fail, we recommend that you pay attention to the correct polarity when connecting.
3. i3-NET
If your system uses multiple controllers, connect them to a i3-NET network. Install the end terminators included in the equipment kit at the ends of the bus.
If you have Modbus controled devices, connect them to the bus and connect them to the RS-485 connector. Install the end terminators included in the equipment kit at the ends of the bus.
A 5V and 3.3V controller outputs are provided to power the sensors.
Connect sensors, switches and other devices to the controller inputs. The inputs of the controller use connectors with spring-loaded contacts, which provides convenience and reliability of connection of conductors with a cross-section up to 1.5 mm2.
Atom Carbon +R3
TYPE OF INPUT / # OF INPUT
1-2
3-11
12-16
17-22
TYPE OF INPUT / # OF INPUT
TYPE OF INPUT / # OF INPUT
1-2
1-2
3-11
3-11
12-16
12-16
17-22
17-22
Analog (thermistor, photoresistor, etc.)
✖
✔
✖
✖
TYPE OF INPUT / # OF INPUT
Analog (thermistor, photoresistor, etc.)
1-2
✖
3-11
✔
12-16
✖
17-22
✖
Digital (motion sensors, light level sensors, switches, buttons, etc.)
✔
✔
✔
✔
TYPE OF INPUT / # OF INPUT
Digital (motion sensors, light level sensors, switches, buttons, etc.)
1-2
✔
3-11
✔
12-16
✔
17-22
✔
Interface (1-Wire sensors)
✔
✔
✖
✖
TYPE OF INPUT / # OF INPUT
Interface (1-Wire sensors)
1-2
✔
3-11
✔
12-16
✖
17-22
✖
Atom Carbon N +R3
TYPE OF INPUT / # OF INPUT
1-2
3-11
12-16
TYPE OF INPUT / # OF INPUT
TYPE OF INPUT / # OF INPUT
1-2
1-2
3-11
3-11
12-16
12-16
Analog (thermistor, photoresistor, etc.)
✖
✔
✖
TYPE OF INPUT / # OF INPUT
Analog (thermistor, photoresistor, etc.)
1-2
✖
3-11
✔
12-16
✖
Digital (motion sensors, light level sensors, switches, buttons, etc.)
✔
✔
✔
TYPE OF INPUT / # OF INPUT
Digital (motion sensors, light level sensors, switches, buttons, etc.)
1-2
✔
3-11
✔
12-16
✔
Interface (1-Wire sensors)
✔
✔
✖
TYPE OF INPUT / # OF INPUT
Interface (1-Wire sensors)
1-2
✔
3-11
✔
12-16
✖
The operation of network controllers requires remote access to configure, manage and control their operation. To ensure these capabilities, at least one of the controllers must be able to connect to a wired or wireless network. In the Atom product line, these are the N modification controllers. Don't forget to connect the network cable to the controller or configure access to the home Wi-Fi network .
After turning on the controller, you need to download the i3 Home mobile application and configure the system.
LED indicators do not light
1. Check the supply voltage on the controller
2. Check the polarity of the power supply
The device is turned on but not in the application settings
1. Make sure Wi-Fi and bluetooth are turned on on your smartphone or tablet2. Verify that the home network password is specified correctly in the controller settings
Inputs do not respond to signals from sensors or switches
1. Check that the connection is correct2. Check that the connections at the controller and sensor terminals are secure3. Check the login configuration to the type of sensor or switch
Output status indicators are not lit
Check that the output settings are correct in the controller settings
The output status indicator lights up, the device does not turn on, or responds incorrectly
1. Check that the connection is correct and reliable2. Check the device for damage
Didn’t find the answer to your question?
You can contact the technical support chatbot.Found a mistake on the site? Help us fix it!